Nfpa Fire Door Gaps
Maximum allowable perimeter gap is 1 8 for wood doors 1 8 1 16 for metal doors.
Nfpa fire door gaps. In fact nfpa 252 methods of fire test of door assemblies which is the predominant fire door test that nfpa 80 relies on uses test criteria where the gaps are a sixteenth of an inch smaller than what nfpa 80 currently allows for metal doors. Hence these gap sizes are regulated. Contains information on maximum gap allowances for different types of fire doors. Under the bottom of a door.
Nfpa 80 currently allows a maximum bottom gap of 3 4 and a maximum of 1 8 for the perimeter of the swinging fire doors. Also a fire door will typically have three quarters of the rating of the surrounding. Nfpa 80 fire doors and other opening protectives. 1 8 meeting edges for a pair of doors.
Methods of fire tests of door assemblies 2015 standardized fire door test. So then what are the gap allowances for fire doors that won t allow fire and smoke to pass through. If the gap around the fire door is too big then fire and smoke will be able pass through. This means a door with a two hour rating for example can be expected to resist combustion for two hours in the event of a fire.
Fire ratings measure the amount of time that a door is able to contain the spread of fire as tested according to nfpa guidelines. 3 4 between door and frame. You can now access all of the great resources from keyes life safety and compliance one group in one place. The clearance under swinging fire doors is frequently found to be greater than the maximum allowable gap size currently allowed by nfpa 80.
There s never been any documentation that technically supports the disparity between what nfpa. This standard regulates the installation and maintenance of assemblies and devices used to protect openings in walls floors and ceilings against the spread of fire and smoke within into or out of buildings. 1 8 for more detailed gap information refer to nfpa 80 section 6 3 1 7 and section. In general clearance for those allowed gaps are as follows.
1 1 1 with the exception of fabric fire safety curtain assemblies this standard addresses assemblies that have. Too often gaps around the perimeter of a fire door will be greater than the gap allowances for fire doors acceptable by nfpa 80. A 1 1 see annex k for general information about fire doors. The ability for swinging fire doors to resist the passage of fire and smoke and to comply with the applicable standards is affected by the gap sizes around the perimeter of the door and as a result the maximum allowable gaps around swinging fire doors are codified.
Fire door gap solutions 6 gaps what does the code say.